Technical Specification |
10 |
20 |
30 |
| |
Output range kW |
3,9-13 |
6,1-22 |
6,1-30 |
| |
Boiler weight kg |
261 |
310 |
310 |
| |
Max. Permissible feed pressure mbar |
0,10 |
0,10 |
0,10 |
| |
Permissible operating pressure bar |
3,0 |
3,0 |
3,0 |
| |
Max. Permissible flow temperature °C |
95 |
95 |
95 |
| |
Water capacity L |
55 |
76 |
76 |
| |
Electric supply V/Hz |
230/50 |
230/50 |
230/50 |
Equipment up to 1500kW on request
|
We reserve the rights for technical modifications |
| |
|
|
|
|
| |
Dimensions (mm) |
|
|
|
| A |
Length overall |
|
|
|
| A1 |
Length boiler |
|
940 |
940 |
| A2 |
Length boiler plus distance to BSD centre line |
1120 |
1120 |
1120 |
| A3 |
Length boiler plus distance to flue pipe centre line |
955 |
1030 |
1030 |
| B |
Width (maximum for access) |
590 |
590 |
590 |
| C |
Height |
1168 |
1268 |
1268 |
| D |
Smoke flue diameter |
130 |
130 |
130 |
| E |
Height to flue pipe top edge |
925 |
1025 |
1025 |
| F |
Height to BSD top edge |
435 |
435 |
435 |
| |
Height to flow connection (1”) |
891 |
991 |
991 |
| |
Height to return flow connection (1”) |
701 |
801 |
801 |
| |
Height to feed and drain connection (1/2”) |
264 |
264 |
264 |
| |
|
|
|
|
| |
|
|
|
|